Two-Wire 4-20mA Two-Electrode Ozone Sensor

Brand Name : Daruifuno

Model Number : OZ1.2

Certification : CE, ISO

Place of Origin : China

MOQ : Negotiable

Price : Negotiable

Payment Terms : T/T

Delivery Time : 1-45 work days

Packaging Details : carton

Product Name : Ozone sensor

Product Model : OZ1.2

Measuring range : 0~0.5/2/5/10/20ppm

Pressure Range : 0 ~ 1bar (Flow cell)

Temperature Range : 0 ~ 45 ℃

Response Time : T90: approx. 3 min. (brine approx. 5 min.)

Flow Rate : 15-30 l/h (33 – 66 cm/s)

Contact Now

Two-Wire 4-20mA Two-Electrode Ozone Sensor For Drinking Water, Direct Drinking Water, Service Process Water

Two-electrode system ozone sensor OZ1.2, used in drinking water, direct drinking water, service and process water, measuring water without surfactant, optional range 0~0.5/2/5/10/20ppm

The functional characteristics of the ampere film ozone sensor include high sensitivity and fast response, which can accurately measure the ozone concentration in water. Its advantages are strong anti-interference ability, suitable for various water quality environments, and long service life. It is suitable for drinking water and industrial water treatment to ensure water quality safety.

Two-Wire 4-20mA Two-Electrode Ozone Sensor

Specifications

Two-Wire 4-20mA Two-Electrode Ozone Sensor

OZ1.2

Indicator Ozone
Application

Swimming pool water, drinking water, service water, process water
The water must not contain any surfactants (tensides)!

Measuring system Membrane covered, amperometric 2-electrode system

Electronic

Analog version: - voltage output

- not galvanically isolated electronics

- analog internal data processing

- output signal: analog (analog-out/analog)

Digital version: - electronic is completely galvanically isolated

- digital internal data processing

- output signal: analog (analog-out/digital)

or

digital (digital-out/digital)

mA-version: - current output analog

- not galvanically isolated electronics

- output signal: analog (analog-out/analog)

Information about the

measuring range

The actual slope of a sensor can vary production-related between 65% and 150% of the nominal slope

Note: With a slope > 100% the measuring range is reduced accordingly.

(Ex.: 150% slope → 67% of the specified measuring range)

Slope drift

At repeatability conditions

(25 °C, pH 7,2 in drinking water)

Approx. <- 1% per month

Working temperature

Measuring water temperature: 0 … +45 °C

(no ice crystals in measuring water)

Ambient temperature: 0 … +55 °C

Temperature

compensation

Automatically, by an integrated temperature sensor
Sudden temperature changes must be avoided

Max. allowed working pressure

Operation without retaining ring:

- 0.5 bar

- no pressure impulses and/or vibrations

Operation with retaining ring in Flow cell:

- 1.0 bar,

- no pressure impulses and/or vibrations (see option 1)

Two-Wire 4-20mA Two-Electrode Ozone Sensor

OZ1.2

Flow rate

(Incoming flow velocity)

Approx. 15-30 l/h (33 – 66 cm/s) in flow FLC, small flow rate dependence is given
pH-range pH 1 – pH 11
Run-in time First start-up approx. 1 h
Response time T90 : approx. 15 sec.
Zero point adjustment Not necessary
Calibration At the device, by analytical determination
Interferences

Cl2: factor 0.03
ClO2: factor 0.7

Absence of the disinfectant Max. 24 h

Connection

mV version:

Modbus version:

4-20 mA version:

5-pole M12, plug-on flange

5-pole M12, plug-on flange

2-pole terminal

or

5-pole M12, plug-on flange

max. length of sensor cable (depending on internal signal processing) analog < 30 m
digital

> 30 m are permissible

Maximum cable length depends on application

Protection type

5-pole M12 plug-on flange: IP68

2-pole terminal with mA-hood: IP65

Material Semipermeable membrane, PVC-U, ABS

Size

Diameter:

Length: mV version

Modbus version 4-20 mA version

approx. 25 mm

approx. 190 mm (analog signal processing)

approx.. 205 mm (digital signal processing)

approx. 205 mm

approx. 220 mm (2-pole-terminal)

approx. 190 mm (5-pole-M12)

Transport +5 … +50 °C (sensor, electrolyte, membrane cap)

Two-Wire 4-20mA Two-Electrode Ozone Sensor

OZ1.2

Storage

Sensor: dry and without electrolyte no limit at +5 … +40 °C

Electrolyte: in original bottle protected from sunlight at +5 … +35 °C min. 1

year or until specified EXP-Date

Membrane cap: in original packing no limit at +5 … +40 °C

(used membrane caps can not be stored)

Maintenance

Regularly control of the measuring signal, min. once a week

The following specifications depend on the water quality:

Change of the membrane cap: once a year (depending on the water quality)

Change of the electrolyte: every 3 - 6 months

Two-Wire 4-20mA Two-Electrode Ozone Sensor

Option 1:

Retaining ring

- When operating with pressures >0.5 bar in flow cell

- Dimensions retaining ring 29 x 23.4 x 2.5 mm, slitted, PETP

- Different positions for groove selectable(on request)

Two-Wire 4-20mA Two-Electrode Ozone Sensor

Two-Wire 4-20mA Two-Electrode Ozone Sensor

Technical Data

1. OZ1.2 (analog output, analog internal signal processing)
A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical
isolation.

Two-Wire 4-20mA Two-Electrode Ozone Sensor

Measuring range

in ppm

Resolution

in ppm

Output

Output

resistance

Nominal

slope

in mV/ppm

Voltage

supply

Connection
OZ1.2H-M12 0.005…2.000 0.001

0…-2000 mV

1 kΩ

- 1000

±5 - ±15 VDC

10 mA

5-pole M12 plug-on flange

Function of wires:

PIN1: measuring signal

PIN2: +U

PIN3: -U

PIN4: signal GND

PIN5: n. c.

OZ1.2N-M12 0.05…20.00 0.01 - 100
OZ1.2HUp-M12 0.005…2.000 0.001

0…+2000 mV

1 kΩ

+1000

10 - 30 VDC

10 mA

5-pole M12 plug-on flange

Function of wires:

PIN1: measuring signal

PIN2: +U

PIN3: power GND

PIN4: signal GND

PIN5: n. c.

OZ1.2NUp-M12 0.05…20.00 0.01 +100

(Subject to technical changes!)

2. OZ1.2 (analog output, digital signal processing)
Analog-out / digital
-The power supply is galvanically isolated inside of the sensor.
-The output signal is galvanically isolated too, that means potential-free.

Two-Wire 4-20mA Two-Electrode Ozone Sensor

Measuring

range

in ppm

Resolution

in ppm

Output

Output resistance

Nominal

Slope

in mV/ppm

Power supply Connection
OZ1.2H-An-M12 0.005…2.000 0.001

analog

0…-2 V

(max. -2.5 V)

1 kΩ

- 1000

9-30 VDC

approx. 20-56 mA

5-pole M12 plug-on

flange

Function of wires:

PIN1: measuring signal

PIN2: +U

PIN3: power GND

PIN4: signal GND

PIN5: n. c.

OZ1.2N-An-M12 0.05…20.00 0.01 - 100
OZ1.2H-Ap-M12 0.005…2.000 0.001

analog

0…+2 V

(max. +2.5 V)

1 kΩ

+1000
OZ1.2N-Ap-M12 0.05…20.00 0.01 +100

(Subject to technical changes!)

3. OZ1.2 (digital output, digital signal processing)
-The power supply is galvanically isolated inside of the sensor.
-The output signal is galvanically isolated too, that means potential-free.

Two-Wire 4-20mA Two-Electrode Ozone Sensor

Measuring

range

in ppm

Resolution

in ppm

Output

Output resistance

Power supply Connection
OZ1.2H-M0c 0.005…2.000 0.001

Modbus RTU

There are no terminating resistors in the sensor.

9-30 VDC

approx. 20-56 mA

5-pole M12 plug-on flange

Function of wires:

PIN1: reserved

PIN2: +U

PIN3: power GND

PIN4: RS485B

PIN5: RS485A

OZ1.2N-M0c 0.05…20.00 0.01

(Subject to technical changes!)

4. OZ1.2 4-20 mA (analog output, analog internal signal processing)
A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical
isolation.
4.1 Electrical connection: 2 pole terminal clamp

Two-Wire 4-20mA Two-Electrode Ozone Sensor

Measuring

range

in ppm

Resolutio n

in ppm

Output

Output

resistance

Nominal

slope

in mA/ppm

Voltage

supply

Connection
OZ1.2MA0.5 0.005…0.500 0.001

4…20 mA

uncalibrated

32.0

12…30 VDC

RL 50Ω…RL 900Ω

2-pole terminal

(2 x 1 mm²)

Recommended:

Round cable

4 mm

2 x 0.34 mm²

OZ1.2MA2 0.005…2.000 0.001 8.0
OZ1.2MA5 0.05…5.00 0.01 3.2
OZ1.2MA10 0.05…10.00 0.01 1.6
OZ1.2MA20 0.05…20.00 0.01 0.8

(Subject to technical changes!)

4.2 Electrical connection: 5 pole M12 plug-on flange

Two-Wire 4-20mA Two-Electrode Ozone Sensor

Measuring

range

in ppm

Resolution

in ppm

Output

Output

resistance

Nominal

slope

in mA/ppm

Voltage

supply

Connection
OZ1.2MA0.5-M12 0.005…0.500 0.001

4…20 mA

uncalibrated

32.0

12…30 VDC

RL 50Ω…RL 900Ω

5-pole M12

plug- on flange

Function of wires:

PIN1: n. c.

PIN2: +U

PIN3: -U

PIN4: n c.

PIN5: n. c.

OZ1.2MA2-M12 0.005…2.000 0.001 8.0
OZ1.2MA5-M12 0.05…5.00 0.01 3.2
OZ1.2MA10-M12 0.05…10.00 0.01 1.6
OZ1.2MA20-M12 0.05…20.00 0.01 0.8

(Subject to technical changes!)

Spare Parts

Type Membrane cap Electrolyte Emery O-ring
For all OZ1.2

M20.2
Art. no. 11011.1

EOZ1/W, 100 ml
Art. no. 11101

S1
Art. no. 11908

14 x 1.8 silicone
Art. no. 11805

(Subject to technical changes!)


Product Tags:

Drinking Water Ozone Sensor

      

Direct Drinking Water Ozone Sensor

      

Service Process Water Ozone Sensor

      
 Two-Wire 4-20mA Two-Electrode Ozone Sensor Manufactures

Two-Wire 4-20mA Two-Electrode Ozone Sensor Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Suzhou Delfino Environmental Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)